Link Search Menu Expand Document
Version 1.5
 Subsection 7.1.1: Fixed Displacement Up Section 7.1: Boundary Conditions Subsection 7.1.3: Fixed Shell Rotation 

7.1.2 Fixed Shell Displacement

Certain shell element formulations used in FEBio have two sets of displacement degrees of freedom. One for the front-face of the shell, and one for the back face. The usual displacement degrees of freedom are used for the front-face of the shell, and the shell displacement degrees of freedom are used for the back-face of the shell. This boundary condition allows you to fix the back-face shell degrees of freedom.