Link Search Menu Expand Document
Converted document
 Subsection 4.10.3: Solvent Supply Materials Up Subsection 4.10.3: Solvent Supply Materials Section 4.11: Chemical Reactions 

4.10.3.1 Starling Equation

The material type for Starling's equation for fluid supply is “Starling”. The following material parameters need to be defined:
<kp> hydraulic filtration coefficient, [L /F t]
<pv> effective fluid pressure in external source, [P]
<qc sol=”n”> osmotic filtration coefficient, [L /n t]
<cv sol=”n”> effective solute concentration in external source, [n/L ]
The fluid supply is given by Starling's equation, where is the effective fluid pressure in the multiphasic material.
Example:
This example defines a solvent supply material of the Starling type for a multiphasic mixture containing one solute.
<solvent_supply type="Starling">
  <kp>0.001</kp>
  <pv>0.1</pv>
  <qc sol="1">1e-5</qc>
  <cv sol="1">150</cv>
</solvent_supply>


 Subsection 4.10.3: Solvent Supply Materials Up Subsection 4.10.3: Solvent Supply Materials Section 4.11: Chemical Reactions